verified_user Licensed plumber & chargeman workspace_premium 1-year warranty forum 15-min reply

Aircond Repair — KL & Selangor

Capacitor, drain pump, PCB, fan motor, compressor. We diagnose before we sell parts. Same-day for most common faults. RM 80–120 diagnostic, waived if you proceed with repair.

troubleshoot Diagnose before parts price_check RM 80–120 diagnostic, waived if you proceed today Same-day for common faults verified All major brands
buildQuick booking

Get a quote in 15 min

  • forumMessage us on WhatsApp with a photo or short description
  • request_quoteWe send a fixed-price quote within 15 minutes
  • eventYou confirm. Technician arrives within the agreed window
  • verifiedPhoto summary on completion + 1-year warranty on installs
forum Book on WhatsApp

Reply within 15 min · Mon–Sun 08:00–22:00

Common faults we repair

Six categories cover almost every callout we get.

ac_unit

AC not cooling

Dirty coils (chemical wash), low refrigerant (leak detection + repair), capacitor failure, PCB failure (inverter units), compressor failure.

water_drop

Water leaking from indoor unit

Blocked drain line (90% of cases), sloped drain, cracked drain pan, condensate pump failure.

volume_up

AC making noise

Fan motor bearing failure, loose bracket, refrigerant flow noise (low gas), compressor rattle.

power_off

AC not turning on

Capacitor, fuse, ELCB tripping, PCB failure, thermostat failure.

flash_on

AC tripping ELCB

Capacitor short, compressor short, water ingress to electrical, ELCB itself faulty.

air

Strange smell

Mould (needs chemical wash), drain pan biofilm, refrigerant leak.

Pricing

Labour + parts, typical ranges. Quote in writing before any parts go in.

RepairLabour (RM)Parts (RM)Total typical (RM)
Capacitor replacement8035–80115–160
Drain pump replacement10080–180180–280
Inverter PCB120250–600370–720
Fan motor (indoor)100150–350250–450
Fan motor (outdoor)120200–450320–570
Compressor replacement250–400600–1,800850–2,200
Refrigerant leak repair (location + braze)150–30080–250230–550

Our diagnostic process

Five steps before we sell you a part.

01

Visual + auditory

We check the obvious before testing anything. Wrong-sized fuse, loose bracket, visible leak.

02

Electrical

Multimeter test on capacitor, contactor, PCB voltage, motor windings.

03

Refrigerant

Manifold gauge test, temperature differential check.

04

Diagnosis

We tell you what's actually wrong and the repair-vs-replace economics if relevant.

05

Quote in writing

Before any parts go in.

Repair vs replace decision

We'll tell you straight when replacement makes more economic sense than repair. Common cases:

memory

Inverter PCB over RM 600 on a 5+ year old unit

Replacement usually wins.

compress

Compressor on any unit over 7 years

Replacement almost always wins.

science

R22 system needing major refrigerant work

Phase-out makes replacement strategic.

trending_down

Multiple major repairs in 12 months

Pattern suggests systemic decline.

You make the call; we give you the numbers.

Frequently asked questions

Most likely (in order of frequency): dirty coils needing chemical wash, low refrigerant from a leak, capacitor failure on the outdoor unit, or PCB failure on inverter units. We diagnose before quoting — RM 80–120 call-out, waived if you proceed with repair.

Ready when you are

We answer WhatsApp within 15 minutes during operating hours (Mon–Sun, 08:00–22:00).

chat